To View Other Products - Click Here
Ident No: 0008800900
The C 7000 system is the first IKA® calorimeter with a completely dry device structure for measuring the calorific value of liquid and solid samples. The temperature is recorded directly in the digestion system. This enables measurement times in the range of 3 to 7 minutes (depending on the sample).
The system can manage up to 8 different digestion vessels via coding.
High sample frequency
Exact and reproducible calorific value determination according to ISO 1928
Reduction of routine work through automated measurement process
Automatic detection of the digestion vessels
Interfaces for scales, printer and PC
User-friendly software C 5040 CalWin for measurement data management and control
Digestion vessels can be converted to disposable crucibles C 14
The C 7000 basic equipment set 1 consists of:
C 7000 measuring cell
C 7010 digestion vessel , standard
C 7002 cooling system
C 48 oxygen station
Technical specifications
Measuring range max. 30000 J.Measurement mode double dry (ISO 1928) YesMeasuring time double dry approx. 3 minReproducibility double dry (1g benzoic acid NBS39i) 0.2% RSDWorking temperature max. 30 ° CTemperature measurement resolution 0.0001 KCoolant temperature 12 - 30 ° CIdent No: 0008801400
The C 7000 system is the first IKA® calorimeter with a completely dry device structure for measuring the calorific value of liquid and solid samples. The temperature is recorded directly in the digestion system. This enables measurement times in the range of 3 to 7 minutes (depending on the sample).
The system can manage up to 8 different digestion vessels via coding.
High sample frequency
Exact and reproducible calorific value determination according to ISO 1928
Reduction of routine work through automated measurement process
Automatic detection of the digestion vessels
Interfaces for scales, printer and PC
User-friendly software C 5040 CalWin for measurement data management and control
Special vessel for halogen and sulfur digestion - Digestion vessels can be converted to disposable crucibles C 14
The C 7000 basic equipment set 2 consists of:
C 7000 measuring cell
C 7012 digestion vessel, halogen resistant
C 7002 cooling system
C 48 oxygen station
Technical specifications
Measuring range max. 30000 J.Measurement mode double dry (ISO 1928) YesMeasuring time double dry approx. 3 minWorking temperature max. 30 ° CTemperature measurement resolution 0.0001 KCoolant temperature 12 - 30 ° CCooling medium permissible operating pressure 9 bar