To View Other Products - Click Here
IKA calorimeter C 200 h
Ident No: 0008803700
The C 200 h package is predestined for learning and teaching purposes at schools, technical colleges and universities. Due to its semi-automatic isoperibolic measurement mode, it is also suitable for industrial laboratories with a small number of analyzes. With the standardized and space-saving combustion calorimeter C 200 the calorific values of liquid and solid samples are determined.
The delivery of the C 200 h package includes:
C 200 calorimeter measuring cell
C 5012 halogen-resistant, catalytically activated digestion
vessel C 200.2 conversion set for C 5012
C 248 oxygen station
consumables for installation and calibration
Water and oxygen filling and emptying are carried out manually with the C 200 h package. With a correspondingly high analysis volume, however, automation of the water cycle is easily possible. You will need the separately available C 200.RC hose set and the RC 2 basic cooler.
The catalytically activated, halogen-resistant digestion vessel C 5012 was specially designed for the combustion or digestion of samples containing halogen and sulfur (> 3%). The material of the digestion vessel (Hastelloy) prevents the corrosion of the vessel, which is triggered by samples with a high chlorine content. The catalytically active inner surface leads to higher recovery rates if an analysis of halogens and sulfur is required after the combustion.
Four different operating modes enable the user to control the measuring times as required.
Isoperibole measurement time: approx. 17 min.
Dynamic measuring time: approx. 8 min.
Manual measuring time: approx. 17 min. (Operator- dependent) Time-controlled
measuring time: 14 min
. ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
The measurement process is monitored and visualized using the C 6040 Calwin software, software for device control and evaluation, available as an accessory. The data obtained can also be exported to Excel, Word, SQL, LIMS etc. for further processing. It is also possible to operate several calorimeters simultaneously on one PC. The PC is not included in the scope of delivery and must be provided by the user.
Technical specifications
Measuring range max. 40000 J.Measuring mode dynamic 25 ° C YesMeasuring mode isoperibol 25 ° C YesMeasuring time dynamic approx. 8 minMeasuring time isoperibol approx. 17 minReproducibility dynamic (1g benzoic acid NBS39i) 0.1% RSDReproducibility isoperibol (1g benzoic acid NBS39i) 0.1% RSDIdent No: 0010002379
The C 200 auto package enables the C 200 to be operated with a fully automated water circuit and is particularly suitable for laboratories with a low number of samples. The water circulates in a closed circuit and is kept at a constant temperature by the RC 2 basic chiller. This shortens the test preparation time for the user and leads to even more reproducible results.
The scope of delivery of the C 200 auto package includes:
C 200 calorimeter measuring cell
C 5010 digestion vessel C
248 oxygen station
RC 2 basic circulation cooler
C 200.RC hose set
Consumables for installation and calibration
The calorific values of liquid and solid samples are determined using the standard and semi-automatic combustion calorimeter C 200. The C 200 is mainly used for teaching and learning purposes at schools, technical colleges and universities. By automating the water cycle, it is now particularly attractive for industrial laboratories with a small number of analyzes.
Four different operating modes enable the user to control the measuring times as required.
Isoperibole measurement time: approx. 17 min.
Dynamic measuring time: approx. 8 min.
Manual measuring time: approx. 17 min. (Operator-dependent)
Time-controlled measuring time: 14 min
The calorific value is measured, for example, in accordance with DIN 51900, ISO 1928; ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
The measurement process is monitored and visualized with the C 6040 CalWin, a software for device control and evaluation, available as an accessory. The data obtained can also be exported to Excel, Word, SQL, LIMS etc. for further processing. It is also possible to operate several calorimeters simultaneously on one PC. The PC is not included in the scope of delivery and must be provided by the user
Technical specifications
Measuring range max. 40000 J.Measuring mode dynamic 25 ° C YesMeasuring mode isoperibol 25 ° C YesMeasuring time dynamic approx. 8 minMeasuring time isoperibol approx. 17 minReproducibility dynamic (1g benzoic acid NBS39i) 0.1% RSDReproducibility isoperibol (1g benzoic acid NBS39i) 0.1% RSDIKA calorimeter C 200 h auto
Ident No: 0010002387
The C 200 h auto Package enables the C 200 to be operated with a fully automated water circuit and is particularly suitable for laboratories with a low number of samples. The water circulates in a closed circuit and is kept at a constant temperature by the RC 2 basic chiller. This shortens the test preparation time for the user and leads to even more reproducible results.
The scope of delivery of the C 200 h auto package includes:
C 200 calorimeter measuring cell
C 5012 halogen-resistant, catalytically activated digestion vessel
C 248 oxygen station
C 200.2 conversion kit for C 5012
RC 2 basic chiller
C 200.RC hose set
Consumables for installation and calibration
The calorific values of liquid and solid samples are determined using the standard and semi-automatic combustion calorimeter C 200. The C 200 is mainly used for teaching and learning purposes at schools, technical colleges and universities. By automating the water cycle, it is now particularly attractive for industrial laboratories with a small number of analyzes.
The catalytically activated, halogen-resistant digestion vessel C 5012 was specially designed for the combustion or digestion of samples containing halogen and sulfur (> 3%). The material of the digestion vessel (Hastelloy) prevents the corrosion of the vessel, which is triggered by samples with a high chlorine content. The catalytically active inner surface leads to higher recovery rates if an analysis of halogens and sulfur is required after the combustion.
Four different operating modes enable the user to control the measuring times as required.
Isoperibole measurement time: approx. 17 min.
Dynamic measuring time: approx. 8 min.
Manual measuring time: approx. 17 min. (Operator-dependent)
Time-controlled measuring time: 14 min
The calorific value is measured, for example, in accordance with DIN 51900, ISO 1928; ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
The measurement process is monitored and visualized with the C 6040 CalWin, a software for device control and evaluation, available as an accessory. In addition, the data obtained can be exported to Excel, Word, SQL, LIMS etc. for further processing. It is also possible to operate several calorimeters simultaneously on one PC. The PC is not included in the scope of delivery and must be provided by the user.
Technical specifications
Measuring range max. 40000 J.Measuring mode dynamic 25 ° C YesMeasuring mode isoperibol 25 ° C YesMeasuring time dynamic approx. 8 minMeasuring time isoperibol approx. 17 minReproducibility dynamic (1g benzoic acid NBS39i) 0.1% RSDReproducibility isoperibol (1g benzoic acid NBS39i) 0.1% RSDWorking temperature max. 25 ° CTemperature measurement resolution 0.0001 K